Search This Blog

Tuesday, March 8, 2011

Ionic-Ultrasonic Skin care machine

Ionic-Ultrasonic Skin care machine

Ionic-Ultrasonic Skin care machine

  • item#: 13979
  • Retail price: US$30.80
  • Wholesale Price: 25.50

  • Start from: 1 Unit(s)
  • Description:

    Product type: ZHF-CM-3
    Resource-ionic only: DV6V
    Current : Max .20mA
    Resource-switching power input: AC 100-240V
    Resource-switching power output: DC 15v/0.8A
    Power consumption: Max.300 mA
    Dimension: 95mm*55mm*45mm
    Ultrasonic frequency:3 MHz
    Weight:49g 

    Before operating 
    Power confirmation
    Remove the battery box cover, install four 1.5V button battery. Align the poles (+ and _ properly when inserting the batteries.
    Operation procedure for testing ultrasonic working
    A.Connecting the switching power, place the appliance on a flat surface and put several drops of water on  the ultrasonic waves generator
    B.Turn power on and then select one of the levels “low” or “high”
    C.If the water on the ultrasonic waves generator vibrates ,the ultrasonic wave are produced
    [if !supportLists]-->Remove any jewelry I.E. earrings, rings, necklace, watch and so on
    [if !supportLists]-->Cleanse your face and remove any make-up gently and thoroughly with cleansing lotion or other facial cleansing liquid 

    Operating method
    Ionic cleansing (induct-out) caring 
    if supportLists]-->Apply appropriate portion essence on your face and avoid eye area. Please ensure the treatment area is well covered with the essence.
    [if !supportLists]-->Turn on electricity
    [if !supportLists]-->
    operation order:
    (1) push Ion + button once  the machine works at ionic-out of low level meanwhile the clean indicator on
    (2) push Ion + button once more and the machine works at ionic-out of high level
    (3)push Ion +button third times and the machine turn off
    (4) In any level of ionic-out, you can turn to ionic-in function by pushing the ion-button
    (5) In any function and in any level, you can turn on sonic function too ,then the sonic-ion indicator on and ionic function change to low level automatically
    <!--[if !supportLists]-->When you use ionic-out or ionic-in function, you must hold the Hand Electrode during operating. Glide it slowly in the order indicated in the diagram
    <!--[if !supportLists]-->After 5 minutes caring time, power will be off automatically 

    Nutrition (induct-in) caring
    It should be done after ionic-out caring 
    <!--[if !supportLists]-->Apply appropriate portion essence on your face and avoid eye area. Please ensure the treatment area is well covered with the essence.(ensure your face and the cosmetic cotton tissue are thoroughly moisturized)
    <!--[if !supportLists]-->
    Turn on electricity
    (1) push Ion + button once  the machine works at ionic-in f high level meanwhile the nutrition indicator on
    (2) push Ion + button once more and the machine works at ionic-in of high level
    (3)push Ion +button third times and the machine turn off
    (4) In any level of ionic-in, you can turn to ionic-out function by pushing the ion+button
    (5) In any function and in any level, you can turn on sonic function too ,then the sonic-ion indicator on and ionic function change to low level automatically
    When you use ionic-out or ionic-in function,you must hold the Hand Electrode during operating.Glide it slowly in the order indicated in the diagram 

    Ultrosonic caring operating 
    Basic method
    [if !supportLists]-->Apply appropriate portion essence on your face and avoid eye area. Please ensure the treatment area is well covered with the essence. And apply appropriate portion essence on the probe.
    [if !supportLists]-->Connecting the switching power. Turn power on and then sonicare indicator is on
    [if !supportLists]-->operation order
    (1) push sonic button once  the machine works at sonic of low level meanwhile the sonic indicator on
    2) push sonic button once more and the machine works at sonic of high level
    (3) push sonic button third times and the machine turn off
    (4) In any level of sonic, you can turn to ionic-out function by pushing the related button and sonic & ion indicator on. Glide it slowly in the order indicated in the diagram. Hold the Hand Electrode during ionic care .
    Wash off remaining beauty gel on face after usage. 

No comments:

Post a Comment